What Is Ovc Alarm In Fanuc Robot3/31/2021
To briefly disable this indication and all UOP signals disable the UOP advices.Hit menu - 0 Next - System 2) Hit N1 and select Specifics 3) scroll down to OPWORK - strike enter 4) scroll to UOPDISABLE 5) modification worth to 1 and hit enter the automaton will no longer work in an automated setting with UOP control until the value is changed back again to Zero.As soon as you notice what happens to a engine with voltage imbaIance, you will want to notice it CLOSE.Today I have always been getting random (but becoming more usually) 409 sp1-30, 414, 424,434 alarms.
Dignostic 720 - 723 all state OVC. The overcurrent alarm only take place when the primary contactor engages. Most of the threads I have found are getting this alarm while spindle will be running. I get a al-30 on the spindle amp and al-01 on the power supply component. What Is Ovc Alarm In Fanuc Robot Manual States IfThe servo maintenance manual states if you have got 30 on spindle amp and 01 on PSM, focus on the PSM. And that causes are usually either imbalance ón the mains, wrong air conditioning reactor, or problem IGBT transistor. The uncommon thing is certainly the check out of IR and Can be current on the PSM check out pins display quite little current, actually when the cóntactor engages and thé sensors sound. Could wrong Phase turn cause this issue Any various other insight Thanks a lot again. As for phase rotation is certainly the coolet water pump going the proper method when changed onpumping Is usually the carousel umbrella electric motor going the right way when you strike the key to move, to go clockwise or counter clockwise Is definitely the Spindle going the appropriate method If all of these are going the correct way I would state the stage rotation can be correct. Way lube pump motor is usually 3 phase and a good one to check. The commute will operate the motor the right direction irrespective of incoming phase rotation. I understand the engine that goes the umbrella ovér to the spindIe for a device change is definitely another one but his is not operating at this period. One matter I discovered is that I am obtaining 8V higher per stage (226) at the PSM major 3 phase than I go through at the primary lugs (218)before the air conditioners reactor and mag contactor. While at idle I go through.02 amps on R,.2 amps on T and T. Will run spindle and see what occurs. At complete spindle quickness the amps were 6.5 (L), 7 (S), 3.5 (T). Dont understand if T becoming half the others will be any problem. Could that be an issue Hate to open up the servos if not really needed. What kind of humidity are you speaking about If you open the electric cab will be it moist inside If therefore get a lover or heater with lover pointed inside to dry it out. I included on when moving the vmc in and have got not finished insulating. I did not find where the cabinet is wet inside of but it will be damn certain wet outdoors. The increase above normal produced by the light bulb will keep any moisture build-up or condensation from developing in the cupboard. The electric motor that goes the umbrella ovér to the spindIe can be 3 stage on mine ánd that will tell you stage turn but yours will be not working yet. Sorry I máy steered you incorrect about path of umbrella telling you phase turn because it probably 1 phase like mine.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |